Installation – Desa CGS2718NA User Manual

Page 17

Advertising
background image

www.desatech.com

113101-01C

17

Figure 20 - Installing Crossover Logs

Crossover
Log (#3)

Pegs

INSTALLATION

Continued

INSTALLING LOGS, MODELS
CLD3018PTA, CLD3018NTA,
CLD3924PTB AND CLD3924NTB

WARNING: Failure to position

the parts in accordance with these

diagrams or failure to use only

parts specifically approved with

this heater may result in property

damage or personal injury.

CAUTION: After installa-

tion and periodically thereafter,

check to ensure that no flame

comes in contact with any log.

With the heater set to High, check

to see if flames contact any log. If

so, reposition logs according to

the log installation instructions

in this manual. Flames contact-

ing logs will create soot.

Each log is marked with a number. These numbers

will help you identify the log when installing. It

is very important to install these logs exactly as

instructed. Do not modify logs. Only use logs

supplied with heater.

1. Place the base of the middle log (#1) in the

U-shaped slots of the grate base. The cutout

on the right of the middle log should fit over

the burner (see Figure 21). Make sure the front

of the middle log is resting on the tabs of the

grate base and the cutout area is centered over

the burner “U” bend.

2. Locate pegs on the bottom of back log (#2).

Slide these pegs into the holes in the grate base

behind the burner (see Figure 22).

3. Slide log (#3) over left end of log (#4). Place

these logs on the grate fingers. Make sure the

notches of the front log line up with the grate

fingers (see Figure 23, page 18).

Figure 21 - Installing Middle Log (#1)

Middle Log (#1)

Tab

Burner

“U” Bend

U-Shaped Slot

Figure 22 - Installing Back Log (#2)

Hole in Grate
Base

Back Log
(#2)

Peg

Burner

Crossover
Log (#4)

Pegs

Advertising