Leprecon AI-512 User Manual

Page 9

Advertising
background image

Each panel has the following features:

Assignable room number from 1 to 8. This is set via a rotary switch on the back of the
panel processor. All panels with the same room number are ‘clones’ of each other;
providing redundant control at more than one location.

Assignable panel number from 1 to 12. This, combined with the room number, provides
a unique identity for each panel.

Jumper-configured Priority setting, either high or low. The system allows locking out
low priority panels to restrict access to the lighting system at certain times.

Button playback panels have from 1 to 12 playback switches, and an ‘off’ switch. Each
switch has an associated LED indicator that is lighted when the playback is on, and off
when the playback is off.

A termination jumper is present on each panel for adding a termination resistor to the
data line. Proper installation requires each end of a daisy-chain communication link to be
terminated.

A 4 pin connector that can be attached to 1 or 2 customer supplied external switches.
These contact closures are reported back to the Architectural Interface, and can be used to
trigger any scene.

The illustration below shows these panel features:

9