Installation, Warning – Montigo H34DL User Manual

Page 13

Advertising
background image

H-Series DL Gas Fireplace

Page 13

XG0140 - 070714

Installation

Figure 14. Top Vented, wall mounted installation with one 90° bend. The vent

run must comply with Venting Graph for Top vent, wall mounted terminations,

Figure 11, 11a, 12, 12a, or 13.

Figure 14a. Top Vented, wall mounted Multi-elbow installation. See Venting

Graph for Top vent, wall mounted terminations, Figure 11, 11a, 12, 12a, or 13.

WARNING:

An inspection of the explosion relief flappers and door

MUST be made prior to lighting the fireplace. Faulty seal

on the door gasket and/or explosion ports will result in

products of combustion leaking into the living space and

may result in carbon monoxide poisoning.

Solid Section

Flex Section

Hearth

150” Max.

Heat

Shield

Termination

Exterior

Wall

Figure 14b. Top Vented, wall mounted Retracted Multi-elbow installation. See

Venting Graph for Top vent, wall mounted terminations, Figure 11, 11a, 12,

12a, or 13.

Figure 13 H42DL* Top Vent Venting Graph for wall mounted terminations,

See Figures 14, 14a, or 14b.

36”

45”

Unacceptable vent run

within shaded area.

A

C

B

Acceptable vent run

within non-shaded area.

If your installation does not fall

within the venting graph parameters,

please contact a local Montigo

dealer for Power Venting options.

Heat

Shield

Termination

Hearth

Exterior

Wall

Flex or Rigid

section

38"Min. H34DL*

42"Min. H38DL*

45"Min. H42DL*

Max. as per graph

Flex Section

Exterior

wall

Solid Section

Termination

Hearth

30” Max.

126” Max.

Heat

Shield