Installation – Montigo H34DL User Manual

Page 20

Advertising
background image

H-Series DL Indoor Gas Fireplace

Page 20

XG0140 - 070714

Installation

Installations in the USA which employ the fans must be grounded in

accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70.
For more information see the Fan Kit Installation Guide included with

the fan kit.

NOTE:

If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.

Figure 25. Wiring diagram for optional fans.

G

L2-WH

L1-BLK

p g

Quick Connect

lu to motor

5/1/60 Supply

G

L1 L2

Wiring for the optional Fan Kit

All H*DL* fireplaces may be equipped with optional fan kits for circulating

heat into the living space.
Installations in Canada which employ the fans must be electrically

grounded in accordance with CSA C22.1 Canadian Electrical Code

Part 1 and/or Local Codes.

Installing the remote On/Off Wall Switch

The H*DL* gas valve may be connected to a wall switch. Do NOT

connect any external power to the remote switch. The valve will

generate its own power on a millivolt circuit or will draw its power from

an AC Connection inside the fireplace, depending on the model of the

unit. Use only low voltage wire, and DO NOT connect any external

power to the remote switch.
Refer to Figure 22, 23, or 24 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.