Installation

Figure 19. Corner installation. (NG Models Only)

Figure 19a. Flex installation. (NG Models Only)

45° Corner Installation.
Attach an EEL-45 / PEL-45 (45° elbow) directly onto the flue collar.

Cut the MXT-20 / PXT-20 to suit, and attach it to the EEL-45 / PEL-

45. Slide the fireplace into position and attach to the termination.

45° or less Corner Installation.
Use an MTO-4 / PTO-4 termination and an MFL-1 / PFL-1 or MFL-2

/ PFL-2 (12" or 24" compressed length) and a frame, if appropriate.

Flex may be turned to obtain desired degree of angle required but

must not exceed 45°.

Note: Through the wall venting kits are also available for both

the Straight and the Corner Installation. The Kit includes a heat

shield, a MFL-1 (f/f) / PFL-1 (f/f) flexible pipe, and a termination with

or without a mounting frame.

Rigid Section

Rigid Elbow

100 or 101

Flex Section

100 or 101