Installation, Installation of rear vent dv, 8" h l – Montigo MW34 DV User Manual

Page 10

Advertising
background image

Page 10 of 21

W3400 Gas Fireplace

Installation

Rear Vent

Figure 17. Model W3400R Venting Graph

0

12 24 36 48 60 72 84 96 108

132

120

144 156 168 180

Horizontal Run (in.)

Hearth

0

12

24

36

48

60

72

84

96

108

8"

H

L

Installation Of Rear Vent DV

A complete W3400R (rear vent) system may comprise up to six
individual components:

A - Termination

PTO-3F (3" length)

B - Stucco Kits

MSR (stucco frame)
BSR-4 (4" brick frame)
BSR-6 (6" brick frame)
MOSR (stucco can)

D - Flex sections

PFL-1 (12" section)

PFL-2 (24" section)
PFL-3 (36" section)
PFL-4 (48" section)

E - Solid sections

PEXT-1 (12" section)

PEXT-2 (24" section)
PEXT-3 (36" section)
PEXT-4 (48" section)

F - 90 degree elbow

MEL-90 (90° elbow)

NOTES:

All dimension lengths for vertical or horizontal runs are

measured from center of the vent pipe.

Venting runs must fall within the limits set by the venting

graph (see Figure 17).

min 8"
max 18"

Figure 18. Multi-elbow installation. Distance 'H' must be a minumum of

50". The vent run must comply with figure 17.