NavCom SF-3050 Logging Data to Internal Memory SurvCE User Manual

NavCom Equipment

Advertising
background image

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050

Rev. A

i

Release - Apr 11

This guide will step you through logging GNSS receiver data to the SF-3050 internal memory port via Carlson
Software’s SurvCE data collector program. The receiver data may be used for post-processing or troubleshooting.

 SurvCE software version 2.30.47 (Beta release) or later is required for this interface

 The procedure which follows applies to version 2.0.22.0a or later of SF-3050 firmware

Procedure

 Create a data logging command file. A sample

file is provided below:

Data Logging Setup.txt:
[OUTPUT]PANICA,ONCHANGE,,FH1
[OUTPUT]??,ONCHANGE,,FH1
[OUTPUT]OK,ONCHANGE,,FH1
[LOGFILE]A:,START
[OUTPUT]MSGVERSION,ONTIME,600,FH1
[OUTPUT]MSGPRODUCTINFO,ONCE,,FH1
[OUTPUT]MSGPRODUCTINFO,ONTIME,600,FH1
[PROFILE]OUTPUT
[OUTPUT]EPHEM1B,ONCE,,FH1
[OUTPUT]ALM1B,ONCE,,FH1
[OUTPUT]ECHODGPSB,ONCHANGE,,FH1
[OUTPUT]CHNLSTATUS1B,ONTIME,1,FH1
[OUTPUT]PVT1B,ONTIME,1,FH1
[OUTPUT]MEAS1B,ONTIME,1,FH1
[OUTPUT]EPHEM1B,ONCHANGE,,FH1
[OUTPUT]ALM1B,ONCHANGE,,FH1
[OUTPUT]SFSTATUS1B,ONTIME,1,FH1

 Copy this file to the data collector

 Connect the data collector to the SF-3050 via either the receiver Bluetooth port or Com1 – RS-232

 Turn the receiver and data collector on and start the SurvCE program

 Establish a connection between the data collector and the SF-3050 (either Rover or Base, as appropriate)

 Select the Equip tab

 Click on GPS Utilities