NavCom SF-3050 Logging Data to Internal Memory SurvCE User Manual
NavCom Equipment
 
Applications Note – Logging Data to Internal Memory SurvCE - SF-3050
Rev. A
i
Release - Apr 11
This guide will step you through logging GNSS receiver data to the SF-3050 internal memory port via Carlson 
Software’s SurvCE data collector program. The receiver data may be used for post-processing or troubleshooting. 
 SurvCE software version 2.30.47 (Beta release) or later is required for this interface
 The procedure which follows applies to version 2.0.22.0a or later of SF-3050 firmware
Procedure
 Create a data logging command file. A sample
file is provided below:
Data Logging Setup.txt:  
[OUTPUT]PANICA,ONCHANGE,,FH1 
[OUTPUT]??,ONCHANGE,,FH1 
[OUTPUT]OK,ONCHANGE,,FH1 
[LOGFILE]A:,START 
[OUTPUT]MSGVERSION,ONTIME,600,FH1 
[OUTPUT]MSGPRODUCTINFO,ONCE,,FH1 
[OUTPUT]MSGPRODUCTINFO,ONTIME,600,FH1 
[PROFILE]OUTPUT 
[OUTPUT]EPHEM1B,ONCE,,FH1 
[OUTPUT]ALM1B,ONCE,,FH1 
[OUTPUT]ECHODGPSB,ONCHANGE,,FH1 
[OUTPUT]CHNLSTATUS1B,ONTIME,1,FH1 
[OUTPUT]PVT1B,ONTIME,1,FH1 
[OUTPUT]MEAS1B,ONTIME,1,FH1 
[OUTPUT]EPHEM1B,ONCHANGE,,FH1 
[OUTPUT]ALM1B,ONCHANGE,,FH1 
[OUTPUT]SFSTATUS1B,ONTIME,1,FH1 
 Copy this file to the data collector
 Connect the data collector to the SF-3050 via either the receiver Bluetooth port or Com1 – RS-232
 Turn the receiver and data collector on and start the SurvCE program
 Establish a connection between the data collector and the SF-3050 (either Rover or Base, as appropriate)
 Select the Equip tab
 Click on GPS Utilities