Block Blk

#

Commands

Example

Response

Control

locate off

locate off

LEDs to flash for a user specified
number of seconds. If omitted, the
value <seconds> will be set to a
default of 120 seconds. The flashing
can be terminated at any time with
locate off.

-

-

address

Address

address <address> Card address

This command will force the module
to check and update its current rack
and slot address. This is normally
only done at start-up.

-

-

filename

filename tdmux103.ffw

filename tddmx321.ffw

<name>'.'<extensio
n>

Firmware update
The <name> part must match the
card's hardware and include a
revision number, and the extension
must be either 'ffw' for FPGA
firmware or 'mfw' for microcontroller
firmware. After running this
command, the board will be ready to
receive its new firmware in Intel-hex
format.

-

-

fin

Fin

ok

Finalize
Finalize the programming of the
microcontroller. See description of
the uC boot loader (separate
document).

misc

0

-

STATUS NOT
AVAILABLE BY
SEPARATE
COMMAND,
ONLY FOUND in conf
0
AND info
RESPONSES!

prog | fin

' ' | ovr

' ' | err

Misc info
prog if the card is freshly
programmed by the boot loader and
the program is still un-finalized. fin is
the normal condition.
ovr if DIP-switch 16 is set to the ON
position and the card is under DIP-
switch control.
Note 1: The info part of misc has
additional functionality when locate is
used: locating <remaining seconds>.
This enables a visible countdown
clock in Multicon GYDA, but is not a
required part of FLP4.