Ers 3.5.1, 5 main x-point modules, Xc-m256128-3ghd – Nevion 3GHD256256L User Manual

Page 16: Main x-point modules, 1 card insertion

Advertising
background image

3GHD256256L / SD256256L Rev. E


nevion.com | 16

3.5 Main X-point modules

– XC-M256128-3GHD

The XC-M256128-3GHD is the main X-point card in the VikinX Modular 256x256 router
frame.

A maximum of two XC-M256128-3GHD cards can be inserted into the 21RU frame, providing
control of signals between each 32x32 X-point module. An FR-256256-MR-3GHD equipped
with 8x 32x32 X-point modules and 2x XC-M256128-3GHD modules builds a 256x256
router; with only 1x XC-M256128-3GHD module inside, the router size becomes 256x128.

Note that it is not possible to build a 128x256 router; only 256x128 or 256x256.

If there are no XC-M256128-3GHD cards in the frame, or the present XC-M256128-3GHD
cards are not working, the user has still the ability to control each of the XC-3GHD-M3232

5

cards in the frame as independent 32x32 routers. This feature is useful when configuring the
router, considering protection of important I/O combinations by configuring them to the same
32x32 I/O part of the VikinX Modular 256x256 router frame.

Input 1-32

Input 33-64

Input 65-96

Input 97-128

Input 129-160

Input 161-192

Input 193-224

Input 225-256

Output 1-32

Output 33-64

Output 65-96

Output 97-128

Output 129-160

Output 161-192

Output 193-224

Output 225-256

3.5.1 Card insertion

To insert an XC-M256128-3GHD card, slide the module along the plastic guide rails into its
position. On both sides of the card tray there is a hole next to each module slot. Use the two
handles, which are located on the front of the module to seat the module.

5

Note that XC-3GHD-M3232(-B) in this chapter also applies to XC-SD-M3232.

XC-3GHD-M3232

XC-M256128-3GHD

Advertising
This manual is related to the following products: