3GHD256256L / SD256256L Rev. E


nevion.com | 9

Sync 1 and 2:

Synchronization signal 1 and 2 (in/out). Black&Burst/composite/tri-
level sync reference input with passive loop-through for vertical
interval switching.
Vertical Interval Switching Point: Manual configuration with options
fully in accordance with SMPTE RP168.

Power Alarm:

Power fail alarm relay contacts. Separate contact pair for each PSU
module that is installed. Contact closes on power failure. See Chapter
3.3.4 for further description.

SW 1:

Configurations switch 1. For address set of Multicon Gyda controlling
the Flashlink section. Switch 1-

3 shall be in “on” position (up), the

others shall be in “off” position. See also description in Chapter 3.7.

SW 2:

Configurations switch 2 (not in use).