2 specifications, 1 mechanics, 2 power supply – Nevion 3GHD256256L User Manual

Page 5: 3 control

Advertising
background image

3GHD256256L / SD256256L Rev. E


nevion.com | 5

2 Specifications

2.1 Mechanics

Dimensions:

HxWxD = 924x483x340mm, (19”, 21RU).

Frame weights:

35.4kg;
Weights above include standard equipment according to
Price List item specification.

Router weights:

3GHD256256L / SD256256L (21RU): 48.2kg
Weight of fully populated router frame.

Backplane card:

256x256 (21RU).

X-point Modules:

-

Main X-point modules: 256x128

-

I/O X-point modules: 32x32

System Controller:

1 Multicon

2

card required, 1 redundant card is optional.

2.1.1 Emission/Immunity and safety standards

Emission/Immunity standards: Compliant with CE EN55103-1 and 2, FCC part 15.
Safety standards:

Compliant with CE EN60950, UL-1950/CSA22.2.

2.2 Power supply

Built-in power supply

4 modules included (2 per section).

Total power consumption:

<600W.

AC Supply voltage range:

90-130VAC / 180-254VAC, switchable, 50-60Hz, 2x300W.

Minimum load:

10% of maximum load.

AC Mains connector:

IEC 320, separate input for each PSU module.

Optional DC/DC power supply:
DC Supply voltage range:

36 - 72VDC, 2x300W.

DC Mains connector:

Screw terminal, separate input for each PSU module.

Alarms:

Power failure alarm on relay contact closure, LED in front,
and Open Collector.

Alarms connector:

RJ45.

2.3 Control

Standard Features:

Serial ports:


Connector:

RS-232/RS-422 for protocol conversion, to VikinX compact
control protocol, or to third party protocols. (2x per Multicon2
card).
DB9, female.

Ethernet ports:

Connector:

10/100BaseT Ethernet bus for external router control with
new protocol. (1x per Multicon2 card).
RJ45.

EDH & Monitoring:


Connector:

Error Detection and Handling integrated in monitoring
outputs.
1 channel available for switch through inputs.
BNC.

Monitored parameters:
(via Multicon2)

-

Loss of signal.

-

Lock and clock rate on reclockers.

-

Module temperature.

-

Internal module voltages.

Status surveillance:

On each board with LED, and via system controller.

Reclocker option:

Bypass of reclocking (from system controller).

Input Equalizer option:

Bypass of input equalization (from system controller).

2

Syscon may be applied instead of Multicon VX-MOD in the router until further notice.

Advertising
This manual is related to the following products: