Nevion 3GHD256256L User Manual

Page 25

Advertising
background image

3GHD256256L / SD256256L Rev. E


nevion.com | 25

Only Nevion provided cable solutions shall be used for connection between
Flashlink modules and the router.

The 2x8 inputs and 16 outputs are found in the router control system (Multicon)
as inputs 257 to 264 and outputs 257 to 272.

For control and monitoring of Flashlink modules, one or two (redundant) Multicon
Gyda
board (s) must be mounted in dedicated slot (s) at the bottom section of the
router.

Input EQs and Output Reclockers must always be activated in Flashlink modules
that are used in the router frame.

Input EQs and Output Reclockers in the router’s signal paths connecting to/from
the Flashlink section must be activated.

When connecting two Flashlink modules via the router, the signal must be looped
externally, via the router’s backplane. And Input EQ and Output Reclocker must
be activated for the employed backplane ports.