3GHD256256L / SD256256L Rev. E


nevion.com | 21

The 10 LEDs on the front of each X-point card indicate the following:

Diode

Red LED

Green LED

BEAT

Blinks when the μController is running
(heartbeat).

SYST.ERR A fault is detected on the card. The

system controller lights, or turns off
this LED. This is used for simplifying
the identification of a module.

SER.CH2

Blinks each time the μController of the
X-point card answers a message from
the system controller on
communication channel 2.

SER.CH1

Blinks each time the μController of the
X-point card answers a message from
the system controller on
communication channel 1.

TEST 1

No special function; for internal testing purpose only.

FAN 2

Fan error, when the fan speed is
outside its normal range. FAN2 is the
innermost fan on the X-point card.

The fan speed of FAN2 is in its normal
range. FAN2 is the innermost fan on
the X-point card.

PWR

Any of the voltages on the card is
outside their legal range.

All internal voltages are OK.

TEMP

The temperature of the card is outside
its legal range.

The temperature of the card is OK.

FAN1

Fan error, when the fan speed is
outside its normal range. FAN1 is the
outermost fan on the X-point card.

The fan speed of the first fan is in its
normal range. FAN1 is the outermost
fan on the X-point card.

EDH.ERR

Indicates EDH status for the selected
monitor output.
The monitoring output monitors the
selected input, but the EDH counter is
on the output.

Note that all alarm ranges are configurable from the system controller.

3.6.4 Service switch and reset button

There are one slide-switch and one push-button switch on the board, as shown in the figures
below.

The push-button switch (SW2001) is the RESET switch. When this button is pushed and
released, the μController of the X-point card resets and restarts its operation with its default
settings, or the settings stored in EEPROM.