Nortec Air Humidification System BS User Manual

Page 24

Advertising
background image

25.05.05-A

page 24 of 30

6. Operation


The system may only be taken into operation by the operator or by a person authorised by him
after putting into operation was accepted by the NORTEC customer service or by persons authorised
by NORTEC. Furthermore it is obligatory that the operator has been introduced into operation by
NORTEC. After putting into operation and introduction into operation, the operator is obligated to
ensure that only trained persons operate the system. This is subject matter of the warranty terms
of NORTEC.


6.1

Switching-off during daily operation

For maintenance works, the exchange of defect or to-be-serviced system components or in the
event of faults in the system, it may be necessary to take the system out of operation. Information
on when to switch off is included in more detail in Chapter 7 (see also the exchange instructions
for the individual devices).

CAUTION: When switching off the system, always ensure to prevent an accidental switching-on (water
supply and voltage supply, depending on the type of switching-off). The employees have to be
informed about the switching-off.


6.1.1 Switching-off

completely

Here parts of the system or even the entire system are/is de-energised and the water supply is
switched off.

Atomiser BS5/10:
Remove the voltage supply plug from the device. The water supply and/or the compressed air
supply can also be interrupted in addition by removing the quick couplings.

CAUTION: Please note that there is a risk of standstill contamination when it is switched off for a
longer period of time (more than 24 hours) (fresh water automatic system not active). It is obligatory
to inform the NORTEC customer service before switching it off completely.


6.1.2 Partial

switching-off


Atomiser BS5/10:
Set the set-point adjuster to 20% r.h. In this case, the fresh water automatic system is still
active.

CAUTION: You can also disconnect the water supply and/or compressed air supply of the
atomisers by removing the quick couplings in order to stop the device from working. This may only
be done in an emergency. Please note that there is a risk of standstill contamination when it is
switched off for a longer period of time (more than 24 hours) (fresh water automatic system not
active).

Advertising