Controller overview, Mua ii controller 3 technical guide features, Figure 1: mua ii controller dimensions – Orion System MUA II Controller User Manual

Page 3

Advertising
background image

MUA II Controller

3

Technical Guide

Features

The MUA II Controller Board is designed with 5 usable analog inputs,
and 5 relay outputs. The controllers input and output capabilities can
be expanded by use of either 2 slot or 4 slot expansion boards that plug
into the MUA II Controller by means of a modular cable. The MUA II
Controller is designed for used with Makeup Air HVAC units. Features

include the following:

Up to 8 Stages of Cooling (4 on board, 4 more with
expansion board)

Up to 8 Stages of Heating (4 on board, 4 more with
expansion board)

External Modulating Heat

Fan Proving Interlock

Supply Air Setpoint Reset From Temperature Input

Dewpoint Setpoint Reset From Humidity Input

Accepts Remote Occupied Signal

Controller Overview

De-Humidification Capable

7 Day, 2 Event per Day Scheduler Built In

14 Day Holiday Scheduler Built In

Internal Trend Logging

Direct Connection With MODGAS II And REHEAT II
Controllers

Most makeup air control configurations can be configured with the
standard MUA II Controller. If the application requires more outputs,
optional relay expansion boards are available from the factory to provide
for additional relay outputs as required. These expansion boards are
installed on eithMUA II Controller board via a modular cable connection.

The available expansion board configurations allow for up to 16
additional binary (relay) outputs. The various expansion boards connect
to the expansion board base. Jumpers must be set according to the
board type installed. Up to 4 Relay Output Expansion Boards can be

installed on the expansion base board connected to the controller.

Figure 1: MUA II Controller Dimensions

RL

Y1

D1

D2

D3

D4

D5

CX3

RAM

EPROM

C3

C2

U6

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

POWER

GND

24VAC

L1

D16

R6

C9

SC1

R1

1

U1

1

D13

C16

VR2

TB4

R27

C13

R10

VR1

C19

C18

U8

CX8

U9

X1

R7

D10

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXPANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D18

D17

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-5

VDC

0-1

VDC

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y2

RL

Y3

RL

Y4

RL

Y5

CX15

(1 MEG)

HH

P1

C21

6.2“

6.6”

7.3”

6.7”

.20 Dia.
Typ. of 4

Advertising
This manual is related to the following products: