Expansion board installation & wiring, Vav/cav controller technical guide 7, Jumper settings – Orion System MUA II Controller User Manual

Page 7: Figure 5: mua ii controller wiring, Figure 6: expansion board jumper settings, Philips, Mua ii controller, 4 relay output expansion board

Advertising
background image

VAV/CAV Controller

Technical Guide

7

7.

Before applying power to the MUA II controller, be sure
to recheck all wiring connections and terminations
thoroughly.

6.

When communication wiring is to be used to interconnect
controllers together or to connect to other
communication devices, all wiring must be minimum 18
gauge, 2 conductor, twisted pair with shield.

Line Voltage

Required VA For

Transformer = 8VA

24VAC

GND

Local Loop RS-485

9600 Baud

G - Fan ON/OFF Only

R - 24VAC

Relay Output Dry Contacts
R2 Thru R5 May Be User Configured For
The Following:
1 - Heating (Aux. Heating)Stages
2 - Cooling (Compressor) Stages
3 - Gas Reheat Control For Dehumidification
4 - External Heat Enable

Note: Up To 16 More Relays Are Available
By Adding Relay Expansion Boards. All
Expansion Board Relay Outputs Are User
Configurable As Listed Above.

Note: All Temperature Sensors Must Be Thermistor Type III Which
Provide 10K Ohms Resistance @77 Deg. F

MUA II Controller

Connect To
Expansion Board
Base (When Used)

Analog Inputs

See Individual Sensor

Wiring Diagrams For

Detailed Sensor Wiring

Connect To Next Controller And/Or

MiniLink PD On Local Loop

For Stand Alone Applications

Connect To System Manager

Warning:
24 VAC Must Be Connected So That All Ground
Wires Remain Common. Failure To Do So Will
Result In Damage To The Controllers.

All Comm Loop Wiring Is

Straight Thru

T to T

R to R

SHLD to SHLD

RL

Y1

D1

D2

D3

D4

D5

CX3

RAM

EPROM

C3

C2

U6

PHILIPS

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

POWER

GND

24VAC

L1

D16

R6

C9

SC1

R1

1

U1

1

MC34064A

D13

C16

9936

VR2

7824CT

M

TB4

R27

C13

R10

VR1

C19

C18

NE5090NPB3192

0PS

U8

CX8

U9

X1

R7

D10

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXPANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D18

D17

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-5

VDC

0-1

VDC

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y2

RL

Y3

RL

Y4

RL

Y5

CX15

(1 MEG)

HH

P1

C21

+

_

0-10 VDC

0r 2-10 VDC

Connect To

External Heat

Device If Used

Figure 5: MUA II Controller Wiring

Jumper Settings

The expansion boards are connected to the MUA II Controller with a
modular cable. Up to 2 Expansion Base Boards can be populated with
expansion boards to provide additional inputs and outputs. The expan-

sion boards can be placed on the expansion base board in any order,
however, the jumpers on the Expansion Base Board must be set cor-
rectly for proper operation. See Figure 6 for correct jumper settings
and jumper locations.

Jumpers
Under
Expansion
Board To Be
Set As Shown

Common

N.O. Contact #6 - Configurable

N.O. Contact #7 - Configurable

N.O. Contact #8 - Configurable

N.O. Contact #9 - Configurable

4 Relay Output Expansion Board

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

K3

K2

4RLY IO BD.

V4

K4

YS101790

TB1

V1

K1

K3

U2

K4

RN1

PCF8574P

U1

T L

HA

AN

I D

ULN2803A/

K2

K1

74HC04N

PHILIPS

P1

CX2

CX1

Relays 6-9

Relays 10-13

Relays 14-17 Relays 18-21

Address Jumpers

Relay Outputs - 6 Through 21

Expansion Board Installation & Wiring

Figure 6: Expansion Board Jumper Settings

Advertising
This manual is related to the following products: