12 standard specifications -26, 12 standard specifications – Quantum Composers LDDC 1550 User Manual

Page 26

Advertising
background image

12-26 |

P a g e

12 Standard Specifications


These specifications are common to both the LDDC and the LSC units. Specifications only
relevant to the LSC unit are shown after the common specifications:

Indoor use in dry conditions only
Ordinary Protection: This product is NOT protected against harmful ingress of moisture.
Class III Equipment (external 15VDC power source)
External Power Supply: Class II (ground connection not required for safety)

o Mains Supply Input: 100-240V ~ 50-60Hz 0.35A
o Output: 15VDC 0.8A

Pollution Degree II (micro-ambient pollution restricted to temporary conductivity caused

by condensation)

Installation (overvoltage) Category II for transient over-voltages
Maximum Relative Humidity: <80%, relative humidity, non-condensing
Operation temperature range of -0

o

C to +40

o

C (+32

o

F to +104

o

F)

Storage and transportation temperature of -40

o

C to +70

o

C (-40

o

F to +158

o

F)

Maximum altitude: 0 to 2000m (6562 ft.)
Weight of the equipment: 0.4kg (0.9lb)
Accessories: External Power Supply (CUI Inc., Model HK-CH12-A15)

MIN

TYP

MAX

UNIT

I/O Configuration

Std DB15

Pulse Mode Options

Single Shot, Pulsed, Burst, and CW

Burst Count

1

65535

Pulses

Internal Rate
Generator

Rate

0.1

100,000

Hz

Resolution

100

ns

Accuracy

25

ns

Jitter (pulse to pulse)

1

ns(rms)

Timing

Pulse Width Range

100n

10

s

Width Accuracy

25

ns

Width Resolution

100

ns

Digital Input

Range

0

5

V

Advertising
This manual is related to the following products: