Scotsman CME256 AutoIQ User Manual

Page 10

Advertising
background image

AutoIQ Controller:

Indicator Lights:

Bin Full: On when bin is full, goes on and
off as ice falls during a harvest cycle.

Freeze: On when the unit is in the Freeze
cycle, blinks when a freeze mode is
pending.

Harvest: On when the unit is in the Harvest
cycle.

Clean: On when the unit is in the Clean
cycle, blinks when preparing for a clean
mode.

Off: On when the unit has been switched
off, blinks when the machine is preparing to
shut off.

Water Error: On when the controller has
identified a problem with the water system.

Refrigeration Error: On when the controller
has identified a problem with the
refrigeration system.

Cycle Definitions:

Freeze: The refrigeration system is
operating to remove heat from the
evaporators. The compressor, fan motor (if
air cooled) and water pump are ON.

Harvest: The refrigeration and water
systems are operating to harvest the ice
cubes. While the compressor is on for the
full cycle, the water pump will be off at the
beginning and inlet water valve will switch
off before the end.

Clean: The Inlet Water Valve opens to fill
the reservoir, The Water Pump starts. The
Clean indicator light is switched ON. A
manually initiated rinse flushes the system.

CME256, 506, 656, 806: AutoIQ™ Cubers

July 2002

Page 10

1

2

3

4

5

6

7

8

9

BIN FULL

FREEZE

HARVEST

CLEAN

OFF

WATER

REFRIGERATION

Reservoir Water

Level Sensor

Bin Control Sensor

Bin Control Sensor

Reservoir & Discharge

Line Thermistors

Low Voltage In/out

Water Valve

Hot Gas Valve
Contactor Coil

Stacking

Future Use

Factory Use

Push Button

Control Switches

Hi Voltage In/out

Water Pump

Air Cooled Fan Motor

Indicator Lights:

Diagnostic Lights

AutoIQ Controller: Wire Connections, Push Buttons, and Indicator Lights

Advertising