Problem or Symptom

Possible Cause

Probable Correction

Unit is off because of a
“Harvest Problem”

Bin controls did not sense
ice falling, unit stayed in
harvest until the maximum
harvest time ran out.

Check bin controls. The bin full light should be
off. If it is on or blinking the bin controls may
be dirty. Clean if dirty. The board and bin
controls may also need to be checked.

Push and release Off button. Push and
release Freeze button. Check machine
operation. Check if ice is made and harvests.

Bin controls or System
Controller may have failed.

See “Unit does not shut off” below..

Other components may
have failed

Check the next page

Cubes are too large

Cube size float sticking.

Check/clean

Cubes are too small

Not enough water

Check for leak in reservoir

Two plate models
making ice thicker on
one plate than another

A - D series - refrigerant
distributor restricted

Change distributor

CME506 E and higher
series - expansion valve
bulbs on wrong suction line

Switch bulbs to correct suction lines

CME506 E and higher
series - one TXV not
metering

Check TXV, replace if there is poor ice
formation on its plate

Low ice capacity

Dirty condenser or filter

Replace filters, clean condenser

Recirculation of air

Block air re-circulation or move condenser

Low refrigerant charge

Check system. If there is a low charge, find
the leak, recover the refrigerant, repair the
leak, replace the dryer, evacuate and weigh in
the nameplate charge.

Cube size set wrong

Re-adjust cube size

Unit does not shut off

Bin control system may
have failed.

Check bin controls. Check bin full light, if off,
place something between the electric eyes.
The bin full light should begin to blink (after 20
seconds of continuous blockage it will glow
steadily). If not, check operation of electric
eyes by unplugging #4 and jumping out the
two pins on the controller (first discharge any
static electricity by touching the cabinet with
the tool). If the bin full light blinks, replace the
bin controls. If it does not blink, replace the
controller. Note: Leaving #4 unplugged and
jumped for 20 seconds will shut the machine
down on a bin full (at the end of the harvest
cycle). It will restart after 4 minutes or may be
reset by pushing the Freeze button.