Review – cm, No ice • water in reservoir • two blink water code – Scotsman CME256 AutoIQ User Manual

Page 48

Advertising
background image

Review – CM

3

• No Ice

• Water in reservoir

• Two Blink Water Code

– Code means Slow or No water fill; low

water level

– 4 Possible Causes:

• Fills too slowly – restricted water supply

• Water not high enough in sump

• System did not sense full sump correctly

• Water valve not opening