Cycle Times (minutes)

System Pressures

Refrigerant Charge, R-404A

Air cooled: 33 ounces

Water cooled: 24 ounces

Typical Compressor Amps

Freeze: single phase = 13

Harvest: single phase = 14

Typical Harvest Ice Weight

6.5 - 7 lb.

Water Cooled:

Discharge Pressure: 240 - 245 PSIG

Hi Pressure Cuts Out at: 450 PSIG

Fan Control Switch - for units so equipped:

Cut In: 240 PSIG + - 20 PSIG

Cut Out: 190 PSIG + - 10 PSIG

Air Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Freeze

9 - 11

12 - 14

Harvest

1:45

1:15

Water Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Freeze

10 - 12

12 - 13

Harvest

1:45

1:15

Air Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Suction: End of Freeze

20 - 21

25 - 27

Suction: Peak in Harvest

89 - 91

115 - 125

Discharge: 5 minutes into Freeze

210 - 220

280 - 290

Discharge: Minimum in Harvest

155

205

Water Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Suction: End of Freeze

24 - 26

24 - 26

Suction: Peak in Harvest

85 - 95

90 - 95

Discharge:

240 PSIG

240 PSIG

Discharge: Minimum in Harvest

155

165

Advertising