Service diagnosis – Scotsman NME1854 User Manual

Page 22

Advertising
background image

NME1854 & FME2404

January 2000

Page 22

SERVICE DIAGNOSIS:

No ice is made, nothing operates

Unit off due to no power

Restore Power

Unit off due to master switch in OFF

position.

Switch master switch to ON.

Unit off due to low water level.

Check water supply, filter, strainer,

float valve. Correct water supply.

Unit off due to ice level sensors

(photo-electric eyes) blocked.

Check/clean ice level sensors.

Unit off due to scale on water level

sensor.

Clean water level sensor.

Unit off due to high pressure control

open.

Check for water interruption (water

cooled) or fan motor failure (air

cooled).

Auger motor hums but does not turn. Auger can’t turn. Circuit board has not

yet shut unit down.

Unit is shut down

Circuit board has shut ice machine

down due to high auger motor amp

draw. Check for cause of high amp

draw, including bearings, gearmotor

condition and scale on auger and in

evaporator.

Low pressure control open

Auger not turning due to: motor

failure; auger relay failure on circuit

board; or gears stripped. Check drive

train.
TXV restricted or not metering. Check

bulb temperature.
Lack of refrigerant. Check for leak.
Check for a restricted system

No power to circuit board.

Check harness

Circuit Board gear motor relay will not

close

Check, replace board

Water level or ice level sensor failed. Check, replace sensor

No ice, auger motor is turning

Compressor contactor coil is open

Check/replace contactor

Compressor will not start

Check start capacitor.
Check start relay
Check compressor windings

Circuit board compressor relay will

not close.

Check, replace board

Unit makes ice, but very slowly.

High discharge pressure because of a

dirty condenser

Clean the air filter and condenser.

Low cap because auger & evaporator

are coated with mineral scale

Clean the water system

Low suction pressure due to low

refrigerant charge

Locate leak. Recover refrigerant,

repair leak, replace dryer, evacuate

and weigh in the nameplate charge

Advertising
This manual is related to the following products: