Installation Limitations:

This ice system is designed to be installed indoors,

in a controlled environment:

Min

Max

Air Temperature

50

0

F

100

0

F

Water Temperature

40

0

F

100

0

F

Water Pressure

20 PSI

80 PSI

Voltage

198 VAC 253 VAC

(Compared to the nameplate)

Operating the machine outside of the limitations is

misuse and can void the warranty.
Water Limitations:

An ice machine is a food manufacturing plant; it

takes a raw material, water, and turns it into a food

product, ice. The purity of the water is very

important in obtaining pure ice and in maximizing

product life. This is not intended as a complete

resource for water related questions, but it does

offer these general recommendations:

1. Check with a water treatment specialist for a

water test, and recommendations regarding filters

and treatment.

2. In most cases, the water used to make ice

should be filtered or treated, depending upon the

water. There is no one type of water filter that will

be effective in all situations. That is why a water

test is important.
RO Water Limitation: Water conductivity must be

no less than 35 microSiemens/cm.

NME1854 & FME2404

May 2001

Page 3

Scotsman Ice Systems are designed and

manufactured with the highest regard for safety

and performance. They meet or exceed the

standards of UL, NSF, and CUL.

Scotsman assumes no liability or responsibility of

any kind for products manufactured by Scotsman

that have been altered in any way, including the

use of any part and/or other components not

specifically approved by Scotsman.

Scotsman reserves the right to make design

changes and/or improvements at any time.

Specifications and design are subject to change

without notice.

FOR THE INSTALLER: Environmental Limitations

Advertising
This manual is related to the following products: