SERVICE DIAGNOSIS

Symptom

Possible Cause

Probable Correction

Water Leak

Drain plugged up

Clean out drain

Tubing cracked

Replace tubing

Condensation on drain tubing

Insulate tubing

Hose off

Reattach hose

Reservoir cover off

Return cover to reservoir

Reservoir cracked

Replace reservoir

Evaporator water seal leaks

Check base of evaporator & drip pan.

If the seal leaks, shut off the water,

remove the auger, replace the water

seal. Check gear motor for water

infiltration.

Excessive water use

Water cooled model, water regulating

valve not adjusted properly.

Adjust to 245 PSIG discharge

pressure

Reservoir float valve leaks thru

Replace float valve or seat

Water cooled model, overcharged

with refrigerant

Recover and weigh refrigerant. Weigh

in correct charge.

Water cooled model, condenser

coated with minerals

Acid clean water cooled condenser.

Excessive ice meltage

Bin drain clogged

Clean out bin drain.

Improper installation of drains, they

are connected.

Drains must be separate.

Poor fit between bin door and door

frame

Adjust or replace

Machine makes too much noise

Evaporator coated internally with

minerals

Clean with Scotsman Ice Machine

Cleaner

Motor bearings dry

Oil or replace motor

NME1854 & FME2404