FOR THE INSTALLER

Final Check List

______1. Is the ice system installed indoors in a

location where the air and water

temperatures are controlled, and where

they do not exceed the design

limitations?

______2. Is there an electrical service disconnect

within sight of the installed machine?

Has the voltage been checked, and

compared to nameplate requirements?

______3. Have all the plumbing connections been

made and checked for leaks?

______4. Has the machine and bin been leveled?

______5. Is there a minimum of 6" clearance at

the back of the machine for proper

service access and air circulation?

______6. Is the water pressure a minimum of 20

psig?

______7. Has the machine been secured to the

bin?

______8. Is there clearance above the top of the

machine for service access?

______9. Is there a water shut off valve installed

near the machine?

______10. Have all of the shipping blocks been

removed?

NME1854 & FME2404

January 2000

Page 8