FIELD CONNECTION

FIELD CONNECTION

FIELD CONNECTION

FIELD CONNECTION AND THERMOSTAT

AND THERMOSTAT

AND THERMOSTAT

AND THERMOSTAT WIRING DIAG

WIRING DIAG

WIRING DIAG

WIRING DIAGRAMS

RAMS

RAMS

RAMS

A.

A.

A.

A.

LOW

LOW

LOW

LOW VOLTAGE (

VOLTAGE (

VOLTAGE (

VOLTAGE (24

24

24

24V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS –

– SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT

SINGLE HEATER PER THERMOSTAT

Ground

N Neutral

L1 Hot (120V)

Continue To

Additional

Heaters

Fused

Disconnect

Switch

Control Box

C Hi

Lo

Two-Stage Thermostat

(field supplied)

High Fire

Low Fire

C Hi

Lo

Two-Stage Thermostat

(field supplied)

High Fire

Low Fire

Control Box

Thermostat Connection

Block

B.

B.

B.

B.

LLLLOW

OW

OW

OW VOLTAGE (

VOLTAGE (

VOLTAGE (

VOLTAGE (24

24

24

24V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS

V) THERMOSTAT CONNECTIONS –

– MULTIPLE HEATERS

MULTIPLE HEATERS

MULTIPLE HEATERS

MULTIPLE HEATERS PER THERMOSTAT

PER THERMOSTAT

PER THERMOSTAT

PER THERMOSTAT

Ground

N Neutral

L1 Hot (120V)

Fused

Disconnect

Switch

Continue To

Additional

Heaters

24 V Transformer

1.5 VA rating per relay

(field supplied)

24 V

Continue To

Additional

Heaters

Control Box

Two-Stage Thermostat

(field supplied)

High Fire

Low Fire

RELAY BOARD

LO

24V

HI

LO

C

HI

LO
FIRE

HI
FIRE

C Hi

Lo

RELAY BOARD

LO

24V

HI

LO

C

HI

LO
FIRE

HI
FIRE

C Hi

Lo

3/16” Quick

Connect Terminals

1/4” Quick

Connect

Terminals

Relay Kit externally

Mounted

(PN 44195000)

Thermostat

Connection Block

Control Box

C.

C.

C.

C.

MANUAL SWITCH

MANUAL SWITCH

MANUAL SWITCH

MANUAL SWITCH CONNECTIONS

CONNECTIONS

CONNECTIONS

CONNECTIONS –

– SINGLE HEATER

SINGLE HEATER

SINGLE HEATER

SINGLE HEATER OPERATION

OPERATION

OPERATION

OPERATION PER

PER

PER

PER DUAL

DUAL

DUAL

DUAL MANUAL SWITCH

MANUAL SWITCH

MANUAL SWITCH

MANUAL SWITCH

Ground

N Neutral

L1 Hot (120V)

Continue To

Additional

Heaters

Fused

Disconnect

Switch

Note: Low Fire Switch MUST stay on during High Fire running.

Control Box

C Hi

Lo

Low Fire

Manual Switch

(field supplied)

Thermostat Connection

Block

High Fire

Manual Switch

(field supplied)

Control Box

C Hi

Lo

Low Fire

Manual Switch

(field supplied)

High Fire

Manual Switch

(field supplied)

Advertising