5.0)

SPECIFICATIONS

Model

Model

Model

Model

No.

No.

No.

No.

Input

Input

Input

Input,

,

,

, Btu/hr

Btu/hr

Btu/hr

Btu/hr

Heat

Heat

Heat

Heat

Exchanger

Exchanger

Exchanger

Exchanger

Length

Length

Length

Length

Total

Total

Total

Total

Heater

Heater

Heater

Heater
Length

Length

Length

Length

Flue Restrictor

Flue Restrictor

Flue Restrictor

Flue Restrictor Plate

Plate

Plate

Plate

I.D. &

I.D. &

I.D. &

I.D. & Part #

Part #

Part #

Part #

Orifice Size

Orifice Size

Orifice Size

Orifice Size

Minimum *

Minimum *

Minimum *

Minimum *

Mounting Height

Mounting Height

Mounting Height

Mounting Height

High

High

High

High

Low

Low

Low

Low

Natural Gas

Natural Gas

Natural Gas

Natural Gas

Propane Gas

Propane Gas

Propane Gas

Propane Gas

@

@

@

@

Horizontal

Horizontal

Horizontal

Horizontal

@

@

@

@

45º Angle

45º Angle

45º Angle

45º Angle

LTU 40 40,000 25,000

30’

16’-10”

1”

#42741040

#31

(0.120)

#49

(0.073)

10’.

9’

LTU 50 50,000 31,500

1-1/8” #42741030 3.3mm (0.130)

#46

(0.081)

11’.

10’

LTU 60 60,000 38,000

1-7/32” #42741020

#27

(0.144)

#43

(0.089)

12’

11’

LTU 75 75,000 50,000

1-7/16” #42741010

#20

(0.161))

#39

(0.099)

13’

12’

* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.

Type

Type

Type

Type

Gas

Gas

Gas

Gas

Gas Pipe

Gas Pipe

Gas Pipe

Gas Pipe

Connection

Connection

Connection

Connection

Tube

Tube

Tube

Tube

Diameter

Diameter

Diameter

Diameter

Flue

Flue

Flue

Flue

Connection

Connection

Connection

Connection

Fresh Air

Fresh Air

Fresh Air

Fresh Air

Connection

Connection

Connection

Connection

Electrical

Electrical

Electrical

Electrical

Supply

Supply

Supply

Supply

Current

Current

Current

Current

Rating

Rating

Rating

Rating

Natural

or Propane

½” MPT

(Male)

3”

4” Round

4” Round

120 Volt, 60Hz,

1 Phase

2.6 Amp

Fuse

Fuse

Fuse

Fuse R

R

R

Rating:

ating:

ating:

ating:

Ignition System (direct spark):

Ignition System (direct spark):

Ignition System (direct spark):

Ignition System (direct spark):

Spark Module: 2 Amp 250V

(for 24V Circuit)

30 second pre-purge period

6.0)

PACKING LIST

A.

A.

A.

A.

Control/Draft Inducer

Control/Draft Inducer

Control/Draft Inducer

Control/Draft Inducer Package

Package

Package

Package

Part Description

Part Description

Part Description

Part Description

QTY

QTY

QTY

QTY

Control Box Assembly .............................................................................................................................. 1
Draft Inducer Assembly (with 4” Starting Collar) ................................................................................. 1
Flue Restrictor Plate (refer to 5.0) for I.D. & part number) ................................................................. 1
Control Fastener Kit (#42787000) ........................................................................................................ 1

Containing:

¼ - 20 Locknuts (#02167010) ............................................................ 6

Gas Connector 5/8” OD x 36” (#30302360) ....................................................................................... 1
Installation & Operation Instructions (#42710010) ........................................................................... 1

CONTROL/DRAFT INDUCER

CONTROL/DRAFT INDUCER

CONTROL/DRAFT INDUCER

CONTROL/DRAFT INDUCER PACKAGE NUMBERS

PACKAGE NUMBERS

PACKAGE NUMBERS

PACKAGE NUMBERS

NATURAL GAS

NATURAL GAS

NATURAL GAS

NATURAL GAS

PROPANE GAS

PROPANE GAS

PROPANE GAS

PROPANE GAS

MODEL NO.

MODEL NO.

MODEL NO.

MODEL NO.

PART NO.

PART NO.

PART NO.

PART NO.

MODEL NO.

MODEL NO.

MODEL NO.

MODEL NO.

PART NO.

PART NO.

PART NO.

PART NO.

LTU40-N7 ............................. #42735510

LTU40-L7 .............................. #42735520

LTU50-N7 ............................. #42735530

LTU50-L7 .............................. #42735540

LTU60-N7 ............................. #42735550

LTU60-L7 .............................. #42735560

LTU75-N7 ............................. #42735570

LTU75-L7 .............................. #42735580

B.

B.

B.

B.

Body Package Descriptions

Body Package Descriptions

Body Package Descriptions

Body Package Descriptions

Part Description

Part Description

Part Description

Part Description

QTY

QTY

QTY

QTY

#42734000, 15Ft. Body Package ......................................................................................................... 1
Containing: #42736000, Pre-assembled 15’ ALC steel tube assembly with reflectors ........ 1

#42762010, Control End Reflector ........................................................................... 1

#42761010, Foot End Reflector ................................................................................ 1

#02125130, #10-24x1/2 Screws .............................................................................. 6

#02189020, #10-16x1/2 Screws .............................................................................. 2

#02266010, Speed Clips ........................................................................................... 14

#42769010, Sliding Clamps ....................................................................................... 6

Advertising
This manual is related to the following products: