NOTICE: Non thermostat con-

trolled heaters may be used as

a vented product. If so, you must

always run heater with chimney

flue damper open and damper

clamp installed. If running heater

with damper open, noncombus-

tible material above the fireplace

opening is not needed. Go to

Installing Damper Clamp Ac-

cessory for Vented Operation,

page 12.

Minimum Noncombustible Material
Clearances

If Not Using Mantel

Note:

If using a mantel proceed to If Using Man-

tel. If not using mantel, follow the information

on this page.

You must have noncombustible material(s) above

the fireplace opening. Noncombustible materi-

als (such as slate, marble, tile, etc..) Must be at

least 1/2" thick. With sheet metal, you must have

noncombustible material behind it. Noncombus-

tible material must extend at least 8" up (for all

models). If noncombustible material is less than

12", you must install the fireplace hood accessory

(24" Models Only). See Figure 5 for minimum

clearances.

INSTALLATION

Continued

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

Heat Resistant
Material

(A)

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

If Using Mantel

You must have noncombustible material(s) above the

fireplace opening. Noncombustible materials (such

as slate, marble, tile, etc.) must be at least 1/2" thick.

With sheet metal, you must have noncombustible

material behind it. Noncombustible material must

extend at least 8" up (for all models). If noncombus-

tible material is less than 12", you must install the

fireplace hood accessory (24" Models Only). Even if

noncombustible material is more than 12", you may

need the hood accessory to deflect heat away from

your mantel shelf. See Figure 5 and Figures 6 and

7, page 11, for minimum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chimney

flue damper open. Go to Installing Damper Clamp

Accessory for Vented Operation, page 12.

Noncombustible

Requirements for

Material Distance (A) Safe Installation
12" or more

Noncombustible
material OK.

Between 8" and 12"

24" Models:

Install fireplace hood
accessory (GA6050,
GA6052, GA6053, see
Accessories, page 26).

18" Model: Noncom-
bustible material OK.

Less than 8"

Noncombustible
material must be
extended to at least
8". See Between 8"
and 12"
, above. If you
cannot extend material,
you must operate
heater with flue damper
open and damper
clamp installed.