Specifications, Replacement parts, Service hints – Desa VFRMV18PB User Manual

Page 26: Technical service, Accessories, Specifications replacement parts

Advertising
background image

www.desatech.com

116412-01B

26

SPECIFICATIONS

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they can’t supply original replacement part(s),

call DESA Technical Service Department at

1-866-672-6040.

When calling DESA, have ready

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

can’t supply original replacement part(s), call DESA

at 1-866-672-6040 for referral information.

When calling DESA, have ready

• model and serial numbers of your heater

• the replacement part number

EQUIPMENT SHUTOFF VALVE
GA5010

For all models. Equipment shutoff valve with 1/8"

NPT tap. Fits 1/2" NPT pipe.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, con-

tact your local propane/LP or natural gas supplier.

ACCESSORIES

Purchase these heater accessories from your local

dealer. If they can not supply these accessories, call

DESA at 1-866-672-6040 for referral information.

You can also write to the address listed on the back

page of this manual.

VFRMV18NB

• Rating (Variable): 20,000/30,000 Btu/Hr

• Gas Type: Natural Gas Only

• Ignition: Piezo

• Manifold Pressure: 3.5" - 1.6" W.C.

• Inlet Gas Pressure (in. of water):

Maximum 10.5" W.C., Minimum* 5.0" W.C.

VFRMV18PB

• Rating (Variable): 23,000/30,000 Btu/Hr

• Gas Type: Propane/LP Only

• Ignition: Piezo

• Manifold Pressure: 10" - 6.3" W.C.

• Inlet Gas Pressure (in. of water):

Maximum 14" W.C., Minimum* 11" W.C.

VFRMV24NB

• Rating (Variable): 24,000/36,000 Btu/Hr

• Gas Type: Natural Gas Only

• Ignition: Piezo

• Manifold Pressure: 3.5" - 1.6" W.C.

• Inlet Gas Pressure (in. of water):

Maximum 10.5" W.C., Minimum* 5.0" W.C.

VFRMV24PB

• Rating (Variable): 26,000/34,000 Btu/Hr

• Gas Type: Propane/LP Only

• Ignition: Piezo

• Manifold Pressure: 10" - 6.3" W.C.

• Inlet Gas Pressure (in. of water):

Maximum 14" W.C., Minimum* 11" W.C.

* For purpose of input adjustment

Manufactured by: DESA, 1769 E. Lawrence St., Russellville, AL 35653
Note:

This appliance has been designed-certified by ANS Z21.11.2b-2004 Unvented Room Heaters

and ANS Z21.60-2003.

Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.