4. Press in and turn control knob clockwise

to the OFF position (see Figure 18).

WARNING: Burners will

come on automatically within

one minute when the switch

is in the ON position after the

pilot is lit.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information in column 1, page 16. If

you don’t smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 18).

Note: You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

7. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the front burner. If

needed, keep pressing ignitor button until

pilot lights.

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 18.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4

through 8.

OPERATING HEATER

Continued

Figure 18 - Control Knob and Ignitor

Button Location, Manual Controlled

9. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

10. Wait one minute and switch selector switch

to the ON position to light burners. Note:

AUTO is only functional when using

GWMT1 or GWMS2 optional accessories.

11. Set flame adjustment knob to any level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

WARNING: Make sure the

selector switch is in the OFF

position when you are away

from home for long periods of

time. Heater will come on auto-

matically with selector switch in

the ON position.

Figure 18 - Pilot

Ignitor
Electrode

Pilot
Burner

Natural

Ignitor
Electrode

Pilot
Burner

Propane/LP

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Remote:

Set se-

lector switch in the OFF position to prevent

draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

1. Turn control knob clockwise

to the

PILOT position.

2. Use remote control manual OFF button.

3. Set selector switch in the OFF position.

Piezo Ignitor

Switch

Control Knob