WARNING: Seal any fresh

air vents or ash clean-out doors

located on floor or wall of fire-

place. If not, drafting may cause

pilot outage or sooting. Use a

heat-resistant sealant. Do not

seal chimney flue damper.

WARNING: Never install

the heater

• in a bedroom or bathroom

unless installed as a vented

appliance, see page 12

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 42"

from the front, top or sides of

heater

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air

for Combustion and Ventilation, page 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for

your unit. If your gas supply is not correct, do not

install in fireplace. Call dealer where you bought

the appliance for proper type of appliance.

INSTALLATION

Continued

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION

WARNING: Maintain the

minimum clearances. If you

can, provide greater clearances

from floor, ceiling and adjoining

wall.

*Measured at 14" depth

Allow adequate clearances for accessibility for

purposes of servicing and proper operation

Carefully follow the instructions below. This will

ensure safe installation into masonry, UL127-

listed manufactured fireplace or listed vent-free

firebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4, page 10.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material must be

4" from the side of the fireplace to the cabinet

(see Figure 4, page 10).

B. Clearances from the top of the fireplace open-

ing to the ceiling should not be less than 42".

MINIMUM FIREPLACE CLEARANCE TO

COMBUSTIBLE MATERIALS

SIDE WALL

16"

CEILING

42"

FLOOR

5"

LOG SIZING REQUIREMENTS

MINIMUM FIREBOX SIZE

LOG

SIZE HEIGHT DEPTH

FRONT

WIDTH

REAR

WIDTH

18"

18"

14"

30"

20.5"

24"

18"

14"

35"

24.5"