Operating heater – Desa VFRMV18PB User Manual

Page 18

Advertising
background image

www.desatech.com

116412-01B

18

OPERATING HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Lighting

Instructions, page 16.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow steps 9 through

11, Lighting Instructions, page 17.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note:

All remote control accessories must be

purchased separately (see Accessories, page

26). Follow instructions included with the

remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions on page 16.

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere

between HI and LO. Slide the selector switch

to the REMOTE position (see Figure 20).

Note:

The burner may light if hand-held

remote was on when selector switch was last

turned off. You can now turn the burner on and

off with the hand-held remote control unit.
IMPORTANT:

Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

Figure 20 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held

remote until burner turns on. Hold the con-

trol button again until burner turns off (see

Figure 21).
To Lock

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.
To Unlock

press both buttons together on hand-

held remote control until the light stops flashing.

The hand-held remote is now unlocked.

Figure 21 - On/Off Hand-Held Remote

Control Unit (HRC100)

THERMOSTAT SERIES (MODEL
HRC200)

The hand-held remote can be operated using ei-

ther the manual mode (MANU) or thermostatic

mode (AUTO) (see Figure 22, page 19). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.
Manual Mode

1. Press the POWER and LOCK buttons

together to turn on the hand-held remote

control.

2. Press the MANU button to turn on the

fireplace.

3. Press the POWER and LOCK buttons

together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons

together to turn on the hand-held remote

control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by press-

ing the TEMP + or - buttons.

Selector Switch in
REMOTE Position

REMOTE
OFF
ON

Piezo
Ignitor

Control Knob

Flame
Adjustment
Knob

Control
Button

Indicator
Light

Advertising