To enable or disable automatic track division:

1

With a recordable disc inserted, and with the
unit in record ready mode, press the

MENU

key (

9

or

6

) repeatedly until

A_Track>XX

is shown, where

XX

may be

ON

or

OFF

.

2

Turn the

MULTI JOG

control

B

or use the

SKIP

keys

I

to change the value to

ON

or

OFF

.

The

A-TRACK

indicator at the top right of the

display lights when the auto track function is
enabled.

Automatic track division can be turned on or off
while recording is taking place.

NOTE

When recording certain types of material (e.g. certain
types of classical music or spoken word) through the

analog or non-DAT/CD/MD digital connections, since
the track divisions are determined by relative silence, it
is possible that spurious track divisions will be inserted.
Under these conditions, it may be better to use manual
track division (see below).

However, if recording through a DAT/MD/CD digital
connection, the track number will be incremented only
when a track division signal is received, followed by a
rise in volume.

Digital direct

As mentioned earlier, the digital direct mode
bypasses some of the input circuitry of the CD-
RW750 (the frequency converter and the digital level
control) to write directly to the disc.

To enable or disable digital direct recording:

1

Ensure that the input source is set to

DIGITAL

(either

COAXIAL

or

OPTICAL

).

2

Press the

DIGITAL DIRECT

key

5

(main unit

only). The display shows

D_Direct XX

where

XX

is

ON

or

OFF

.

3

Press the

DIGITAL DIRECT

key to toggle

between

ON

and

OFF

.

When digital direct recording is enabled, the

DIGITAL

indicator in the display flashes slowly.

NOTE

As mentioned earlier, the digital direct feature bypasses
the frequency converter. Recording is therefore only
possible from sources recorded with 44.1 kHz sampling
frequency.

Rec mute function

The rec mute function allows instant cut-off of the
input signal, and records four seconds of silence on
the disc.

1

While recording is in progress, press the

REC

MUTE

key

G

.

The display shows

REC MUTE

, the meters

stop displaying the current level and the moni-
tored sound is cut.

2

After about four seconds, the unit enters
record ready mode.

NOTE

This function is only available from the remote control
unit. It is not possible to use this function with the main
unit only.

Fade-in and fade-out

To provide smooth beginnings and endings to
recorded tracks, the unit provides fade facilities.

Fade-ins are from –

∞ (silence) to the set input level

(“Input selection” on page 18) and fade-outs go from
the current input volume to silence.

The fade-in and fade-out times can be set indepen-
dently in increments of one second, from 1 second to
24 seconds.

level