reboot - Reboot Output
The Reboot Output command is used to turn a port, or ports, off, and then back on. The purpose is
to ‘reboot’ a
server or device by cycling the power. Ports that are currently off will be turned on. Ports that are currently on will be
turned off, then back on. The reboot time duration for each port is assigned in the rbdelay time option.
Any Port may be referred to by either Port Numbers or Port Names. All ports with identical port names will be rebooted
together (i.e., a Port Group)
The keyword “all” is a valid argument
PDU 4/4> help reboot
Syntax: reboot <b> <p>
Description: Reboot an outlet or group of outlets.
<b> = (box # | all) <d> = disable <dly> = delay <e> = enable
<n> = name <t> = time <p> = (port # | name | all)
Ports and Boxes may be referred to by all, name (implying a group) or number.
Ranges of ports may be specified as 1-4 = 1,2,3,4. All may also be used.
Examples:
Reboot Box 1, Port 8
reboot 1 8
Reboot Box 1, Ports 1, 5, and 7
reboot 1 1,5,7
Cycle all outputs OFF/ON in Box #1
reboot 1 all
If Ports 1,2,3 in Box 2 are defined as SUN2, then reboot 2 SUN2
to Reboot ports 1,2,3 in box 2
Reboot all outputs in all boxes.
reboot 0 all
Note: If any of the selected ports are already ON, they will be power cycled OFF, then after a delay,
back ON. Or if any of the selected ports are OFF, they will be power cycled ON.
rbdelay - Set Reboot Time
The reboot delay command sets the time duration that a Port will remain off before turning back on after issuing a
Reboot Command to the PDU 4/4. The Time duration is adjustable from 1 to 29 seconds. Each Port may be
individually programmed.
PDU 4/4> help rbdelay
Syntax: rbdelay <b> <p> <time>
Description: Time (1 to 29 seconds) an outlet remains off before turning back on.
<b> = (box # | all) <d> = disable <dly> = delay <e> = enable
<n> = name <t> = time <p> = (port # | name | all)
Ports and Boxes may be referred to by all, name (implying a group) or number.
Ranges of ports may be specified as 1-4 = 1,2,3,4. All may also be used.