Specifications, Generic interfacerequirements (120 w and 75 w), E1interface – Verilink AS420 (34-00294) Product Manual User Manual

Page 12: T1 interface, 120 w termination, 75 w termination, E1 equipment interface, Generic interface requirements (120 w and 75 w)

Advertising
background image

4

A S 4 2 0 R e f e r e n c e M a n u a l

Specifications

Generic Interface Requirements (120

and 75

)

E1 Interface

Line Rate:

2.048 Mbps (± 32 ppm)

Framing:

ITU-T G.704 (with or without CRC-4) G.703

Line Code:

HDB3

Input Level:

E1 to 6 decibels

Pulse Width:

244 (± 41) nanoseconds at half amplitude

Pulse Afterkick:

10 to 30 percent of pulse peak

T1 Interface

Line Rate:

1.544 Mbps (± 32 ppm)

Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Level:

0 to -36 decibels

Pulse Width:

344 (± 45) nanoseconds at half amplitude

Pulse Afterkick:

10 to 30 percent of pulse peak

120

Termination

Interface:

RJ-48C

Impedance:

120

, balanced

Output Level:

3.0 (± 0.3) volts (base-to -peak)

75

Termination

Interface:

BNC - coax

Impedance:

75

, unbalanced

Output Level:

2.37 (± 0.24) volts (base-to -peak)

E1 Equipment Interface

N

×

64 kbps rate...

for unframed E1: N = 32;
for framed E1 without CAS: N = 1 to 31;
for framed E1 with CAS: N =1 to 15 and 17 to 31

120

Termination

Interface:

RJ-48C

Impedance:

120

, balanced