Supplied materials, Connections, Dteandnetwork connections – Verilink AS420 (34-00294) Product Manual User Manual

Page 16: User interface port connection, Dte and network connections

Advertising
background image

8

A S 4 2 0 R e f e r e n c e M a n u a l

Supplied Materials

The AS420 is shipped from the factory with the following standard
equipment.

external AC power supply

reference manual

RJ -48 to RJ-48 cables

RJ -48 to DB-15 adapters

Connections

The AS420 has BNC and RJ-48C connectors for the network and equipment
interfaces, a supervisory port and a power connector. The following
paragraphs describe these connections.

DTE and Network Connections

Table 2.1 shows the pinout for the RJ-48C NET and EQUIP connectors.

User Interface Port Connection

Table 2.2 shows the pinout for the RJ- 48C User Interface port.

Table 2.1

RJ-48C Equipment and Network Connector Pinout

Pin

NET

EQUIP

1

Tip In

Tip Output

2

Ring In

Ring Output

4

Tip Out

Tip Input

5

Ring Out

Ring Input

3, 6–8

not used

not used

Table 2.2

RJ-48C User Interface Port Pinout

Pin

User Interface Port

1

Not used

2

RTS*

3

Chassis Ground

4

TXD

5

RXD

6

Ground

7

CTS*

8

not used

Advertising