Verilink User Manual

4-1

Chapter

4

Diagnostics and Troubleshooting

Once elements for an application are installed, configured, and
running, you need a way to make sure that your expectations and
requirements for performance are met.

The DIU 2131 provides several built-in features that make circuit
maintenance and testing possible:

Performance registers are available in the CSU Performance
Monitoring Menu.

DIU 2131 Front Panel

The DIU 2131 front panel has three LEDs for each customer data
port:

Near End Loop

LED

The Near End Loop LED lights yellow when the associated data port
is looped on the DIU.

Far End Loop LED

The Far End Loop LED lights yellow when the associated data port is
looped at the far-end DIU. This occurs only if the loop-up command
was sent by the near-end DIU to the far-end DIU over the T1 circuit.

STAT LED

The STAT (DIU 2131 status) LED is a tri-color indicator which shows
one of the following conditions for each data port:

Lit Green:

DIU is working properly (normal operation).

LEDs

Provide a visual indication of normal and

abnormal conditions for each module.

Loopbacks

CSU and DIU loopbacks can isolate problems in

the signal path. Each loopback includes a

specific portion of the signal path, and different

loopbacks may “overlap” a common area. You

can isolate a problem area by applying a logical

succession of loopbacks and comparing which

loopbacks succeed and which fail.

Test signals

Each CSU can apply a test signal to the circuit

through operator-issued commands.