Performance Monitoring

Verilink IMUX User Manual

4-5

The Loopback A and Loopback B signals are DTE signal lines used
to request loopback operation as described in TR30.2/SP-2976.

NOTE: The labelling is deceptive and does not immediately activate

loopbacks. Combinations of these lines determine loopback.

The following matrix (

Table 4-4

) identifies the loopback

behavior as defined in TR30.2 and the loopbacks supported

by the IMUX.

Table 4-4

Loopback Signals

Signal Line Combinations

TR30.2 Control Behavior

IMUX Behavior

Loopback A - off

Loopback B - off

Loopbacks off

Loops off

Loopback A - on

Loopback B - off

Remote Line Loopback

Loops off

(not supported)

Loopback A - off

Loopback B - on

Local Line Loopback

Loops off

(not supported)

Loopback A - on

Loopback B - on

Local Digital Loopback

Local Digital Loopback