NET/External Clock Connection

2-13

An alternate method of connecting the network is through the Network /External
Clock contacts provided on the rear of the unit. Refer to NET /External Clock
Connection
below.

Disconnection

Notice:

In accordance with FCC Rules, Part 68.218(b), the telephone company must be
notified before disconnecting the CSU/DSU.

NET/External
Clock
Connection

Contacts are provided on the rear of the stand-alone unit to permit connection to an
external timing source (using pins 1 and 2). An alternate method for network connection
is also provided with pins 3-6. Connection information is shown in Table 2-14.

The station clock input on the standard 3001 unit is designed to accept TTL or
bipolar signal levels. The station clock is commonly available as a 64 kHz, bipolar
RTZ signal referred to as a composite clock. The unit, however, also accepts any
unframed all ones bipolar RTZ signal with a level of 1.5 to 4 volts peak and a
frequency of 1.544 MHz or any multiple of 56 or 64 kHz. An RS422/423-
compatible station clock input, with the same range of input frequencies, is also
available as a special option.

Contacts are also provided on the rear of the 12-slot chassis unit to permit connection
to an external timing source (using TB1, pins 1 and 2). The station timing is configured
through the Terminal Interface. Refer to Line Parameters on page 4-15.

Alarm
Connection

The stand -alone unit and the chassis modular unit provide rear panel alarm relay
contacts. These dry (isolated) alarm contacts permit connection to a remote
indicating device.

Stand-alone

Unit

The connection for the stand-alone unit is made on pins 5 and 6 of the
Alarm/Power connector as shown in Table 2-15.

Table 2-14 NET/External Clock Pinout

Pin

External Clock Connection

1

Network Input (Tip)

2

Network Input (Ring)

3

Network Output (Tip)

4

Network Output (Ring)

5

Station Clock (Ring)

6

Station Clock (Tip)

Table 2-15 Alarm/Power Connection

Pin

Function

1

48 VDC Return

2

Signal Ground

3

-48 VDC

4

Frame Ground

5

Alarm Contact

6

Alarm Common