User defined time zone:

Select the customized option and enter the time

zone bias to set a user-defined time zone as figure 2.3-3

Figure 2.3-3

Parameter:

Daylight Bias: The offset added to the Bias when the time zone is in

daylight saving time

Daylight Start: The date that a time zone enters daylight time

− Month: 01 to 12

− Week Day: Sunday to Saturday

− Apply Week (Day:01 to 05, Specifies the occurrence of day in the month;

01 = First occurrence of day, 02 = Second occurrence of day, ...and 05 =
Last occurrence of day)

Hour: 00 to 23

Standard Start: The date that a time zone enters daylight time

− Month: 01 to 12

− Week Day: Sunday to Saturday

− Apply Week (Day:01 to 05, Specifies the occurrence of day in the month;

01 = First occurrence of day, 02 = Second occurrence of day, ...and 05 =
Last occurrence of day)

Hour: 00 to 23

Step 3:

If you would like to use SNTP to sync time with a SNTP V4 Server,

click Time Sync button to setup it as figure 2.3-4.

Figure 2.3-4

Step 4:

After successfully base setup; click Control > System to restart IP

Centrex 6850 to take effect as figure 2.3-5.