ACTi Camera Firmware V.5.12.12 User Manual
Page 68

Firmware User
’s Manual V5.12.12
DO
: To setup DI, please define the
Active level as 0 or 1. If the active level is set as 1, then
camera will change the output voltage to high when this response is activated by an event rule.
The voltage will go back to low when the event ends.
Interval determines the minimum
duration of each DO response( in seconds). DO will remain at the active level during this time,
and if another event triggers DO before the end of the first DO, the second trigger will no take
effect. 0 means there is no minimum duration.
Notification message
Notification messages
may be sent to either an email or a HTTP CGI server. If sent to a CGI
server, it works the same as an URL command, but it does not allow a second message at end of
event. You may configure up to three preset massages. You can configure a message, but
disable it. This will allow you to keep the settings without using it, which will be useful in testing
and troubleshooting.
*Pre-requisites: SMTP server / HTTP CGI server setup.
*Pre-requisites: SMTP server / HTTP CGI server setup.