Large Dehumidifying Dryers

Functional Description

15

Sequence shutdown switch

;

NFPA86, UL, AGA & CGA machinery electrical standards (Gas Dryers)

;

Available supply voltages of 208, 230, 460, 575/3/60 and 400/3/60

2-4 Options

Dewpoint Extend

The Dewpoint Extend option measures the temperature of the moist air as it is bled to the
atmosphere after regeneration. After a period of time, the bleed temperature will rise. This
condition, called "bed breakthrough" indicates that the bed is dry. At bed breakthrough, the
bleed air temperature peaks between 350°F and 400°F.

The regeneration heaters turn off automatically on bed breakthrough for additional energy
savings. A 550°F regeneration temperature will dry the desiccant beds sufficiently to produce
process air dewpoint of -40°F. In a properly sized system, this ultra-low humidity level will
be more than adequate to dry plastics to as little as .003% moisture.

Closed-Loop Regeneration

An optional regeneration closed-loop valve and heat exchanger can be used to close the
regeneration loop during the cooling portion of the regeneration cycle. If this option is
enabled on the dryer, air will be bled to the atmosphere until the heating portion of the
regeneration cycle is finished. Then, the regeneration closed loop valve will direct air through
a water-cooled heat exchanger and back into the regeneration loop (see Figure 2).

Figure 2: Closed Loop Regeneration

AD600-AD1500

Dryer Flow Schematic

Regeneration Closed Loop

Cooling is Activated

Regeneration

Filter

Optional

Regeneration

Closed Loop

Cooler

Regeneration

Blower

Optional

Regeneration

Closed Loop

Valve

Regenerarion

Exhaust

Left Desiccant

Regeneration

Heaters

Dryer Valve

AD600-AD1500

Dryer Flow Schematic

Regeneration Heating is

Activated

Regeneration

Filter

Optional

Regeneration

Closed Loop

Cooler

Regeneration

Blower

Optional

Regeneration

Closed Loop

Valve

Regeneration

Exhaust

Left Desiccant

Regeneration

Heaters

Dryer Valve