AEC AP Series Large Dehumidifying Dryer User Manual

Page 91

Advertising
background image

Large Dehumidifying Dryers

Maintenance

90

1. Access the desiccant canisters by removing the panels on the dryer.
2. Remove the Regeneration Heater Cover.
3. Unscrew the six (6) screws on the Heater Element Mounting Plate.
4. Slide out the heater assembly, taking care to not damage the gaskets.
5. Unscrew the heater loops that need to be replaced.
6. Re-install the new heaters. Securely tighten all fasteners.

Caution!

The heater loops should not touch each other. This will create "hot spots"
and lead to premature heater failure.

7. Insert the heater assembly back into the desiccant canister.
8. Fasten the six (6) screws on the Heater Element Mounting Plate.
9. Re-secure the Regeneration Heater Cover.
10. Re-install the dryer panels.

Figure 17: Regeneration Heater Box Assembly

Regeneration

Heater Cover.

High

Temperature

Gaskets.

Heater Element
Mounting Plate.

Access cover can be

removed in order to

replace desiccant.

Viewing Glass, for

checking the status of

the desiccant inside.

Regeneration

Heaters

High

Temperature

Gaskets.

Stainless Steel

Hollow Core

Desiccant Tank

Desiccant Tank

Mounting

Platform

Advertising