Northfire 42

11

INSTALLATION INSTRUCTIONS

Cont...

MO

SPEED

CONTROL

110F (43ºC) N.O.
THERMAL SNAP

SWITCH

CONVECTION BLOWER

LINE

GROUND

NEUTRAL

SIDE OF GAS

FIREPLACE

120 VAC

white

black

SPEED CONTROL

LINE

GROUND

NEUTRAL

110F (43ºC) N.O. THERMAL

SNAP SWITCH

CONVECTION BLOWER

VENT TERMINATION

1. See ALLOWABLE TERMINATION LOCATIONS and establish a suitable vent termination

location.

2. In heavy snowfall areas make sure vent termination is located where it cannot be blocked by

snow or snow from snow removal equipment.

3. Locate vent termination away from plants, bushes or any other object near the vent

termination that will interfere or obstruct the air flow around it.

4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7ft from grade level or anywhere that it can be a burn hazard

to the public, such as patios and balconies, must be protected with an Archgard approved
termination cage.

WIRING DIAGRAM

ALLOWABLE FIREPLACE LOCATIONS

See venting chart for
maximum and minimum
vertical/horizontal
venting configurations.