Northfire 42, 14 allowable termination locations – Archgard 42-DVT40N User Manual

Page 14

Advertising
background image

Northfire 42

14

ALLOWABLE TERMINATION LOCATIONS

Canadian Installations (1)

US Installations (2)

Canadian Installations (1)

US Installations (2)

A= Clearance ab

ove grade,

veranda, po

rc

h, deck, or

balcon

y

12 inches (30 cm)

12 inches (30 cm)

J= Clearance to

non-mechanical air

suppl

y inlet to building or the

combustion air inlet o an

y o

the

r

appliance

12 inches (30 cm)

9 inches (23 cm)

B= Clearance to

w

indo

w or

door tha

t ma

y be op

ened

12 inches (30 cm)

12 inches (30 cm)

K= Clearance to

a mechanical

air suppl

y inlet

6 feet (1.8

3 m)

3 feet (91 cm)

ab

ove if

w

ithin 10 fe

et (3

m)

horizontally

C= Clearance to

permanentl

y

closed w

indo

w

*

*

L= Clearance ab

ove paved

sidew

alk or p

aved drivewa

y

located on pu

blic propert

y

7 feet (2.1

3 m) +

*

D= Vertical clearance to

ventilated soffit located

above the te

rm

inal w

ithin a

horizontal distance of 2 feet

(61 cm) f

rom

the center line

of the terminal

*

*

M= Clearance un

der verand

a,

porch, deck,

or balcon

y

12 inches (30 cm) ++

*

E= Clearance to

unventilated soffit

*

*

F= Clearance to

outside corner

*

*

G= Cleara

nce to

inside corner

*

*

H= Clearance to

each side of

center line e

xtended

above

meter/

regulat

or assembl

y

3 feet (91 cm)

w

ithin a

height 15 feet (

4.

5 m)

above the

meter/re

gulator a

ssembly

*

L= Clearance to

service

regulator

vent outlet

3 feet (91 cm)

*

(1) In accord

ance w

ith t

he curre

nt

CSA B149.1,

Na

tional Gas and P

ropane Installation Code

(2)

In accordance

w

ith the curre

nt AN

SI Z223.1/N

F

PA

54,

National Fuel

Gas Code

(+) A vent shall not terminate dir

ectly

ab

ove

a side walk or paved

drivew

a

y tha

t is located

bet

w

een t

w

o

single family

d

w

ellings and serves both d

w

ellings

(++) Permitted o

nly

if ver

anda, po

rch, deck, or balcon

y is fully

open

on a minimum of

tw

o

sides beneath the floor.

(*) Fo

r clearanc

es not specified in ANSI Z223.

1/N

F

PA 54 or

CSA B149.1, “Clea

ra

nces shall

be in accord

ance w

ith local installation codes

and the re

quirem

ents of the gas supplier.”