INSTALLATION INSTRUCTIONS

PRECAUTIONS

This appliance must be installed by a qualified gas installer and the
installation must conform to the installation codes.

Provide adequate clearance around air openings of the appliance. Never
obstruct front openings.

Provide adequate clearances for proper operation and servicing of the
appliance.

This appliance must be properly connected to a venting system.

This gas appliance must not be connected to a chimney serving a separate
solid-fuel burning appliance.

Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part
of the control system and any gas control which has been under water.

Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Do not use substitute materials.

Do not abuse glass doors by striking or slamming shut.

Do not use abrasive cleaners.

Use only approved fireplace glass cleaner for cleaning your glass.

LOCATING GAS FIREPLACE

This appliance must be installed in any location that is free of plumbing, electrical wiring and
heating or air conditioning ducts. Select a location that is accessible for venting. See
ALLOWABLE TERMINATION LOCATIONS on page 13.

GAS CONNECTIONS

Have your gas supplier or a qualified gas fitter run a gas supply line into the fireplace. The line
must be properly sized and fitted according to the installation codes. Immediately up stream of the
supply connection, the fitter shall provide an accessible manual shut-off valve and a ⅛ NPT
plugged tapping accessible for connection to a test gauge.

CAUTION:

The appliance and its individual shutoff valve must be disconnected from the gas

supply piping system during any pressure testing of that system at test pressures in excess of ½
psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psig (3.5 kPa). Failure to do so will damage the appliance’s gas
valve. Such damage is not covered by the manufacturer’s warranty.