VENTING - RESTRICTOR PLACEMENT

NOTE:

Vent restrictors are designed to reduce vertical stack action for vent

terminations which will reduce the velocity of incoming combustion air and
not adversely affect the standing pilot or the efficiency of the appliance.

RESTRICTOR PLACEMENT “FOR ROOFTOP VENTED APPLICATIONS ONLY”

WARNING:

These restrictors are only to be installed in the vent system if the vent exceeds 8’

in vertical height, *Restrictor Number 1 below is required and if the vent system
exceeds 15’ vertically, *Restrictor Number 2 below is Required. Installing them
under any other circumstances may cause hazardous venting conditions
and may result in personal injury, property damage or death.

“NOT FOR USE IN SIDEWALL VENTED APPLICATIONS”

Restrictor Number #1

Vertical Venting - Above

Eight Feet (8’)

Restrictor Number #2

Vertical Venting - Above

Fifteen Feet (15’)

Archgard System

Archgard System

In the Archgard system, the

restrictors are placed on the

exhaust outlet on the appliance.

Simpson Dura-Vent

Simpson Dura-Vent

With Simpson Dura-Vent,

locate the restrictor in the exhaust

section fitting into the formed lip.