Northfire 42, 31 servicing – Archgard 42-DVT40N User Manual

Page 31

Advertising
background image

Northfire 42

31

SERVICING

Before servicing, read the terms and conditions of the Archgard warranty at the back of the
manual. Contact the Archgard authorized dealer where you purchased the appliance from and
provide them with details of the problem and the installation information that the installer has
filled in at the back of the manual.

WARNING:

Servicing of this appliance must be conducted by a qualified service

technician

. Improper servicing, adjustment or alteration of this appliance may

cause property damage, personal injury or loss of life. All servicing should be
conducted with the appliance cold. All replacement parts must be authorized by
Archgard for suitability.

Note: the Shutter is set at the factory and normally only requires setting at higher altitudes.

Open the lower grilles.

Unscrew the 2 screws holding the blower speed control panel and remove the panel.

The primary air adjustment wing nut is located behind and to the left of the control valve.

Loosen the wing nut and slide the primary air shutter to the right to increase primary air and
to left to reduce primary air.

Tighten the wing nut after adjustment.

Caution:

Wear gloves when adjusting the primary air with the appliance hot.

INCREASE

DECREASE

ADJUSTMENT WING NUT

PRIMARY AIR SHUTTER

BLOWER SPEED
CONTROL BOX

ORIFICE HOLDINGING BRACKET

ORIFICE

ELBOW FITTING

ADJUSTING PRIMARY AIR

SERVICING UNDER WARRANTY

FLAMES...

The left side shows correct adjust-
ment. The right side shows yellow
sooty flames requiring increase in
shutter opening or cleaning of shut-
ter area due to lint buildup.

Advertising