Northfire 42, 16 installation instructions – Archgard 42-DVT40N User Manual

Page 16

Advertising
background image

Northfire 42

16

INSTALLATION INSTRUCTIONS

Cont...

For best venting performance, here are some general venting rules that we recommend:

1. Use only Archgard or Simpson Dura Vent direct vent systems and components.
2. Maintain a minimum of 1” (26 mm) clearance to combustibles from the outside surfaces of

vertical vents and minimum of 1” (26 mm) sides and bottom, and 2” (51 mm) from top surfaces
of horizontal vents.

3. Observe any local code restrictions, if any, regarding the installation of this type of gas

appliance.

4. Observe the venting chart given in this manual.
5. Use vent spacers between the inside and outside vents at every 3 ft (915 mm) intervals

(Archgard vent kits only).

6. Never slope horizontal vents downwards.
7. Maintain at least a rise of ¼” (7 mm) for every 1 ft (305 mm) of horizontal vent.
8. Terminate the vent with a suitable vent termination supplied by Archgard Part #999-DV-HTC or

Simpson Dura Vent.

9. Support horizontal vents every 3 ft (915 mm) to prevent it from sagging.

VENTING - Continued

VENTING CONNECTION

The intake pipe must be securely fastened to the appliance and to the terminal and all joints
shall be secured using a minimum of 3 screws evenly spaced around the pipe.

Approximately 1” from the end of the 4” pipe outlet at the appliance and at the 4” terminal inlet
apply a bead of Mil Pac ¼” wide. Slide the 4” pipe onto the appliance and secure with 3 screws
evenly spaced to the outlet. Repeat the procedure at the terminal inlet.

Install a vent spacer between the outer and the inner liner to maintain clearances. Spacers
should be installed at every change of direction. (See diagram)

Clearance to combustible material and fire-stops must be installed as required by the installation
codes.

APPROVED VENT COMPONENTS

PART #

DESCRIPTION

999-DV-TVK3

Flex Vent Kit with 36” vent length (includes 999-DV-HTC)

999-DV-TVK5

Flex Vent Kit with 60” vent length (includes 999-DV-HTC)

999-DV-HTC

Horizontal termination head only

999-DV-VSD

Vinyl siding deflector

999-DV-STC

24” Snorkel

999-DV-SDA

Adaptor, Flex to Simpson Dura-Vent

999-DV-SDA

Adaptor, Appliance to Simpson Dura-Vent

DV-GS

Simpson Dura-Vent venting system

Advertising