Northfire 42

8

DIMENSIONS AND CLEARANCES

APPLIANCE DIMENSIONS

3/8 ¾”

SIDE VIEW

FRONT VIEW

TOP VIEW

44”

23 ¼”

6 ½”

4 ½”

BACK

0” to stand-offs

SIDES

0” to stand-offs

TOP

0” to stand-offs

BOTTOM

0”

ADJACENT SIDE WALL 1” to side of faceplate
MANTLE

see diagram

VENT

1” to outside side and bottom surface,
2” to outside top surface.

CLEARANCES TO COMBUSTIBLES

Combustible mantle allowed in

shaded area. Mantle extension

may be increased 1” (25mm)

for each additional 1” (25mm)

increase in clearance height.

Minimum Height From Top

Surround: 12” (304mm)

Minimum Height From Bottom

of Appliance: 46” (1165mm)

MANTLE CLEARANCE

18”

34”

32 ½”

35 ½”

42”

6” (152 mm)

NOTE:

Low profile wooden crowns and

moldings above the unit are not
considered as mantles. I.E. 1” or less
protrusions on the upper mantle facing
are acceptable

½

6 ½”